COMPENSATED NEUTRON
LOGGING TOOL
- 9075

The Compensated Neutron tool contains a two detector, neutron system which uses a 5.0 Curie, Am241Be source to record neutron porosity of the formation. Additionally, the tool also records short and long neutron counts, natural gamma, temperature and a deep guard resistivity.

9075.jpg

Benefits:

Fully downhole digital
Quick automatic setup, unique tool identification
Designed for one-man operation
Can be customized to your specific needs

Features:
Properties Measured:

  1. Natural Gamma:
    2.9 x 10.2 cm (1.125 x 4.5 in.)
    NaI Scintillation Offset: 30.5 cm (12 in.)

  2. Deep Guard Resistivity:
    Upper guard, measure and lower guard electrodes, 3 m (10 ft.)
    Offset for measure electrode:147.3 cm (58 in.)

  3. Neutron Detector, Far Spacing:
    He3 3.8 x 24.4 cm (1.5 x 9.6 in.) 61cm (24 in.) spacing

    Offset: 218.4cm (86 in.)

  4. Neutron Detector, Near Spacing:
    He3 2.9 x 10.1 cm (1.125 x 4.0 in.)
    32.4 cm (12.75 in.) spacing Offset: 241.3cm (95 in.)

  5. Temperature Measurement:
    Thermal temperature on needle sensor.
    Offset: 265.4 cm (104.5 in.)

  6. Radioactive Source:
    5 Ci AmBe 241 neutron source,
    bullplug Offset: 276.9 cm (108 in.)

     

Specifications:

Length: 282 cm (111 in.)

Temperature: 85C (185F)

Diameter: 5.1 cm (2.0 in.)

Pressure: 232 kg/cc (3300 PSI)

Weight: 16.4 kg (36 lb.)

Logging Speed: 9 m/min. (30 ft./min.)

Tool Voltage Required: 70 VDC

 

Tool #:9075

Part #:250050A

 

9075 Product Description

bottom of page