9055 - Multi-Parameter E-Log, Neutron (Deviation Option)
Product Description

Background Information
The 9055 tool is a multi-parameter slim hole mining and hydrology tool which contains a single detector, neutron system using a 1.0 Curie, Am241Be source, to record neutron porosity of the formation. Additionally, the tool also records natural gamma, SP, single-point resistance, and optionally, borehole deviation.
Features
Properties Measured (see diagram) Tool Specifications
1.  Vertical Deviation
3-axis Magnetometers/2-axis Inclinometers
Offset: 53.3 cm (21 in.)

2.  Natural Gamma:
2.5 x 10.1 cm (0.875 x 4.0 in.) NAI Scintillation
Offset: 114.3 cm (45 in.)

3.  Neutron Detector:
He 1.0 x 6.0"
Offset: 248.4 cm (97.8 in.)

 

4.  Neutron Porosity:
Offset: 248.4 cm (97.8 in.)
5.  Spontaneous Potential:
+/- 0.1 mv resolution
Offset: 266.7 cm (105 in.)

6.  Single Point Resistance:
+/- 0.1 ohm resolution
Offset: 266.7 cm (105 in.)
7.  Radioactive source:
1 Curie Am241Be
Offset: 289.6 cm (114 in.)

 

Length:
289.6 cm (114 in.)

Temperature:
60C (140 F)

Diameter:
46 mm (1.8 in.)

Pressure:
232 kg/cm2 (3000 PSI)

Weight:
32 kg (14.51 lbs.)

Logging Speed:
18 m/m (60 f/m)

Tool Voltage Required: 36 V

 
Sensor Response Ranges
Sensor Response Limits Accuracy
Natural Gamma (NG) 0-400,000 API units +/-5%
Spontaneous Potential (SP) -400 - +400 mv +/-5%
Temperature (TEMP) 0 C- 70 C (32 - 160 F) +/-5%
Single Point Resistance (SPR) 0-2,000 ohms +/-5%
Neutron-Neutron (NN) 0-20,000 API +/-5%
X - Y Inclination (XYI) 0-45 degrees +/-0.5 degrees
Azimuth (AZ) 0-360 degrees +/-2 degrees
Cost & Availability
Item Model #
Tool with NG,  SP, SPR, NN, TEMP 9055
Magnetic Deviation Option 9055
Source w/Shield Am 241 Be  
Source Handling Tool  
Deviation Calibration Test Stand  
SP/Resistivity Calibration Box  
Phone: 918-838-9811
Fax: 918-838-1532
Century
Geophysical Corp.
1223 S. 71st E. Ave
Tulsa Oklahoma, 74112
sales@century-geo.com